E001CRITICAL

Air Supply/Exhaust Blockage (Navien)

Navien boiler detected a blockage in the air supply or exhaust venting system and shut down.

What This Error Code Means

The boiler's air pressure switch detected improper venting or combustion air supply.

Common Causes

  • Blocked vent pipe from debris or ice
  • Exhaust pipe improperly sloped causing condensate pooling
  • Combustion air intake screen clogged
  • Vent termination too close to wall or obstruction
  • Bird or pest nest in vent

Affected Brands

Navien

How ROMA Heating Fixes This

  • Inspect entire vent and intake path for blockages
  • Clear debris, ice, or obstructions from venting
  • Check vent slope and condensate drainage
  • Clean intake screen and verify proper termination clearance
  • Test operation and confirm no recurrence