E101HIGH

Flow Switch Error (Navien)

Navien boiler flow switch is stuck open or not detecting water flow during DHW demand.

What This Error Code Means

The flow switch failed to close when hot water was demanded, preventing burner operation.

Common Causes

  • Flow switch stuck or failed
  • Water filter screen clogged
  • Low water pressure in system
  • Air in water lines
  • Flow switch paddle broken

Affected Brands

Navien

How ROMA Heating Fixes This

  • Clean water filter screen
  • Test flow switch continuity
  • Check water pressure and flow rate
  • Purge air from system
  • Replace flow switch if failed